FIELD ENGINEERING AND TECHNOLOGY
Roll over, Revision and Change of Classification Electricity Networks and Electricity Supply - Design and Commissioning unit standards
|
Subfield |
Domain |
Id |
|
Electricity Supply |
Electricity Networks |
16283, 17028, 17568-17572 |
|
|
Electricity Supply - Design and Commissioning |
15560* |
Existing classification names
|
Subfield |
Domain |
Id |
|
Electricity Supply |
Electricity Networks |
16283, 17028, 17568-17572 |
New classification names
|
Subfield |
Domain |
Id |
|
Electricity Supply |
Electricity Supply - Core Skills |
16283, 17028 |
|
|
Electricity Supply - Distribution Networks |
17568 |
|
|
Electricity Supply - Live Work |
17570-17572 |
|
|
Electricity Supply - Transmission Networks |
17569 |
At the request of the Electricity Supply Industry Training Organisation (ESITO), the Qualifications Authority has changed the classification of the unit standards referred to above. The domain listed in the 'existing classifications names' table has been designated as lapsed.
The review of these unit standards is planned to take place during 2008.
Date new versions published September 2004
New comments by date September 2007
Expiry date of new versions of the unit standards December 2008
Reason for the revision
The domain that contained most of the ESITO unit standards, Electricity Networks, had become too big and required splitting into more appropriate classifications. This large domain was also causing issues regarding accreditation of training providers - in particular the accreditation relating to live line work which requires training providers to have specialist plant, equipment, and expertise for training delivery and assessment.
The new domains were identified by industry focus groups and reflect both current and future categories for the electricity supply industry.
*In addition, the opportunity was taken to revise unit standard 15560, which had a misleading title. This unit standard has not been reclassified.
Main changes resulting from the revision
· All the unit standards, apart from unit standard 15560, have been reclassified
· Three unit standards have had minor changes in their titles
· Entry requirements have been changed for unit standard 17569
· The term 'enterprise' has replaced by 'industry' throughout the unit standards
· Special notes have been updated for consistency of style and to reflect changes in compliance requirements
· Minor adjustments and corrections have been made to purpose statements, elements, performance criteria, and ranges
· Unit standard 17569 has had some content changes.
Impact on existing provider accreditations
Appropriate extensions to provider accreditations have been negotiated between ESITO and individual providers. This is due to safety and physical equipment requirements for programme delivery within some domains.
Impact on Accreditation and Moderation Action Plan (AMAP)
AMAP 0120 has been updated to reflect the reclassification changes.
Impact on existing qualifications
The following ESITO qualifications are affected by this revision and reclassification and will be revised accordingly.
|
Ref |
Qualification Title |
|
0869 |
National Certificate in Electricity Supply (Cable Jointer - Low Voltage) (Level 3) |
|
0872 |
National Certificate in Electricity Supply (Live Line Mechanic - Transmission) (Level 4) |
|
0874 |
National Certificate in Electricity Supply (Line Mechanic - Distribution) (Level 4) with optional strands in Glove and Barrier, and Hot Stick |
|
0889 |
National Certificate in Electricity Supply (Operator) (Level 3) with strands in Hydro Operations, and Network Operations |
|
0892 |
National Certificate in Electricity Supply (Network Operator) (Level 4) |
|
0917 |
National Certificate in Electricity Supply (Technician) (Level 4) with strands in Control and Instrumentation, Power Technician, and HVDC Technician; and an optional strand in Electrical Services |
|
0921 |
National Certificate in Electricity Supply (Electrical) (Level 4) with optional strands in Electrical Fitter Networks, and Electrical Fitter Hydro |
No other standard setting bodies' qualifications are affected.
Summary of main changes to standards' classification, titles, levels, and credits
The following table shows the changes made to the standards. All changes are in bold.
|
Id |
Domain |
Title |
Level |
Credit |
|
15560 |
Electricity Supply - Design and Commissioning |
Commission and re-commission electricity generation plant Commission and re-commission plant in the electricity supply industry |
6 |
12 |
|
16283 |
Electricity NetworksElectricity Supply - Core Skills |
4 |
8 | |
|
17028 |
Electricity NetworksElectricity Supply - Core Skills |
Demonstrate the requirements for holding permits on high voltage electrical equipment |
3 |
2 |
|
17568 |
Electricity NetworksElectricity Supply - Distribution Networks |
Restore supply of electricity in a distribution environment |
4 |
6 |
|
17569 |
Electricity NetworksElectricity Supply - Transmission Networks |
Replace transmission towers and tower cross arms Replace transmission tower and tower cross arms |
4 |
12 |
|
17570 |
Electricity NetworksElectricity Supply - Live Work |
Carry out short term inspections of tower structures up to line voltage live line MAD Carry out short term inspections of structures up to line voltage live line MAD |
3 |
6 |
|
17571 |
Electricity NetworksElectricity Supply - Live Work |
Repair and replace mid span joints on live electricity network transmission lines Repair and replace mid-span joints on live electricity network transmission lines |
4 |
12 |
|
17572 |
Electricity NetworksElectricity Supply - Live Work |
Prepare working zone for applying protective coatings to tower steel within MAD |
3 |