Field           Planning and Construction

 

Review of Drainlaying unit standards

 

Subfield

Domain

ID

Plumbing, Gasfitting and Drainlaying

Drainlaying

30529-30531, 30534, 30535, 30538, 30539, 30577-30579, 30600, 30601, 30612, 30613

 

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council (Waihanga Ara Rau WDC) reviewed the unit standards listed above.

 

Date new versions published                                                               May 2024

 

Planned review date                                                                              December 2029

 

Summary

 

Waihanga Ara Rau WDC reviewed these unit standards in line with the scheduled 5-year review cycle to update them to align to current industry practice, and to ensure that they are fit for purpose.

 

A series of Technical Advisory Group (TAG) meetings were held between November 2022 and November 2023 to complete this review.  The TAG consisted of industry and provider representatives with consent to assess, and representatives from industry stakeholder organisations including the Plumbing, Gasfitting, and Drainlaying Board and the Ministry of Business, Innovation and Employment.

 

Following the review, public consultation was held in November and December 2023.  Feedback received was reviewed and decisions were made in consultation with the TAG group representatives resulting in the changes below.

 

Main changes

 

·         Guidance information, legislation, performance criteria and range statements were amended across the suite of unit standards to reflect the content and scope of the work, and to align with current industry practice.

·         Minor wording changes were made across the suite for clarity and to meet current industry terms.

·         Unit standard 30529 had the title amended and credits were reduced to 3 to accurately reflect the notional hours required for learning and assessment completion.

·         Unit standards 30531, and 30578 were designated as expiring without replacement.  This is due to the maintenance component not being completed at the time of installation and this was a barrier for completion.

·         Three new unit standards (33326, 33328 and 33330) have been developed with separate installation and maintenance outcomes.

·         Unit standard 30539 was designated as expiring and replaced by two new unit standards (33357 and 33358) with the installation outcomes and maintenance outcomes separated.

·         Unit standards 30579, 30601, 30612 and 30613 had their titles amended to better reflect the outcomes and to align with current industry terms.

·         Unit standard 30600 had the title amended to reflect industry terms, and the credits were increased to 5 to accurately reflect the notional hours required for learning and assessment completion.

 

Category C and D unit standards will expire at the end of December 2028

 

The last date for assessment of superseded versions of Category B unit standards is 31 December 2028

 

Impact on existing organisations with consent to assess

 

Current consent for

Consent extended to

Nature of consent

Classification or ID

Level

Nature of consent

Classification or ID

Level

Standard

30539

4

Standard

33357, 33358

4

 

Detailed list of unit standards – classification, title, level, and credits

 

All changes are in bold.

 

Key to review category

A

Dates changed, but no other changes are made – the new version of the standard carries the same ID and a new version number

B

Changes made, but the overall outcome remains the same – the new version of the standard carries the same ID and a new version number

C

Major changes that necessitate the registration of a replacement standard with a new ID

D

Standard will expire and not be replaced

 

Planning and Construction > Plumbing, Gasfitting and Drainlaying > Drainlaying

ID

Title

Level

Credit

Review Category

30529

Make as-built drawings and record variations to job specifications for drainlaying jobs

Prepare as-built drawings and record variations to job specifications for drainlaying jobs

4

5

 

3

B

30530

Demonstrate knowledge of the installation and maintenance of foulwater drains

4

10

B

30531

Install and maintain foulwater drains

4

5

D

30534

Demonstrate knowledge of wet and dry inspection chambers

3

2

B

30535

Install inspection chambers

3

2

B

30538

Demonstrate knowledge of installation, commissioning, and maintenance of on-site wastewater treatment systems

4

12

B

30539

 

33357

 

33358

Install, commission, and maintain on-site wastewater treatment systems

Install and commission on-site wastewater treatment and disposal systems

Maintain on-site wastewater treatment and disposal systems

4

 

4

 

4

8

 

7

 

3

C

30577

Demonstrate knowledge of the installation and maintenance of stormwater handling systems

4

9

B

30578

Install and maintain stormwater handling systems

4

4

D

30579

Install and complete wingwall structures for stormwater handling systems

Install wingwall structures for stormwater handling systems

4

2

B

30600

Demonstrate knowledge of pumps used in drainlaying systems

Demonstrate knowledge of pumped drainage systems

4

3

 

5

B

30601

Install pumps for drainlaying systems

Install pumps for drainage systems

4

2

B

30612

Demonstrate knowledge of trade waste interceptor traps

Describe trade waste systems

3

4

B

30613

Install food grease interceptor traps

Install trade waste interceptor traps

3

2

B

33326

Maintain drainage systems

4

2

NEW

33328

Install stormwater handling systems

4

3

NEW

33330

Install foulwater drains

4

4

NEW