Level 2

Select, use, and care for tools and equipment used in the installation of compliant passive fire protection

Word  PDF

Version 1

31917 Unit Standard 5 Credits

View Education Organisations with Consent to Assess  »

This unit standard is for the training of fire stopping specialists. People credited with this unit standard are able to: select and use simple measuring devices; select, use, and care for engineering hand tools; and select, use, and care for portable hand-held engineering power tools used in the installation of compliant passive fire protection.

Consent & Moderation Requirements:

CMR 13 Word PDF

Standard-setting body:

Competenz

Level 3

Demonstrate knowledge of passive fire protection

Word  PDF

Version 2 This unit standard replaced unit standard 17709 and unit standard 17710.

26422 Unit Standard 10 Credits

View Education Organisations with Consent to Assess  »

This unit standard covers the underpinning knowledge for people who need to inspect passive fire protection (PFP) systems in buildings. People credited with this unit standard are able to demonstrate knowledge of: the compliance schedule regime; fire compartmentation and escape routes; PFP features; and inspection and maintenance requirements of PFP

Consent & Moderation Requirements:

CMR 13 Word PDF

Standard-setting body:

Competenz

Demonstrate knowledge of the fundamentals of passive fire protection systems

Word  PDF

Version 1

29157 Unit Standard 4 Credits

View Education Organisations with Consent to Assess  »

This unit standard covers the underpinning knowledge of passive fire protection (PFP) systems in buildings. People credited with this unit standard are able to demonstrate knowledge of: the Fire Cells and Fire Resistance Ratings (FRR), the passive fire systems and associated products, smoke separations, standards and approvals required for Passive Fire Protection products, obligations and responsibilities when penetrating/altering/disturbing passive fire protection systems.

Consent & Moderation Requirements:

CMR 13 Word PDF

Standard-setting body:

Competenz

Demonstrate knowledge of passive fire protection system elements and products, and installation practices

Word  PDF

Version 1

31915 Unit Standard 10 Credits

View Education Organisations with Consent to Assess  »

This unit standard is for the training of fire stopping specialists. People credited with this unit standard are able to demonstrate knowledge of: legislation, standards, and codes for passive fire protection installation and quality control; documentation required for installation and compliance of passive fire systems; roles of people in achieving compliant passive fire protection; fire resistance of building elements; passive fire products; and installation practices for compliant passive fire protection.

Consent & Moderation Requirements:

CMR 13 Word PDF

Standard-setting body:

Competenz

Install compliant passive fire protection building elements and products

Word  PDF

Version 1

31916 Unit Standard 35 Credits

View Education Organisations with Consent to Assess  »

This unit standard is for the training of fire stopping specialists. People credited with this unit standard are able to: plan and prepare for installation of compliant passive fire protection building elements and products; install compliant passive fire protection building elements and products; manage and seal service penetrations; and complete installation documentation and reporting.

Consent & Moderation Requirements:

CMR 13 Word PDF

Standard-setting body:

Competenz

Level 4

Inspect passive fire protection as part of a routine inspection

Word  PDF

Version 2 This unit standard replaced unit standard 17711.

26423 Unit Standard 35 Credits

View Education Organisations with Consent to Assess  »

This unit standard covers routine inspections of passive fire protection (PFP) in buildings to confirm ongoing compliance with the requirements of the compliance schedule. Routine inspections of PFP are detailed in Specified Systems SS 15 of the Compliance Schedule Handbook, and assume that the inspector works with a pre-defined compliance schedule which specifies the systems and inspections required. People credited with this unit standard are able to: prepare for a routine inspection and verification; carry out a routine inspection; and verify completion of the inspection, maintenance, and reporting procedures of passive fire protection (PFP).

Consent & Moderation Requirements:

CMR 13 Word PDF

Standard-setting body:

Competenz

Inspect and verify passive fire protection for compliance with the building consent

Word  PDF

Version 2 This unit standard replaced unit standard 17711.

26424 Unit Standard 40 Credits

View Education Organisations with Consent to Assess  »

This unit standard covers inspections of passive fire protection (PFP) in new or altered buildings for the purpose of determining compliance with a Building Consent. People credited with this unit standard are able to: prepare for inspection of PFP; inspect PFP for compliance with a Building Consent; and document and report on the inspection.

Consent & Moderation Requirements:

CMR 13 Word PDF