Domain - Electricity Supply - Design and Commissioning
TOP > Engineering and Technology > Electricity Supply > Electricity Supply - Design and Commissioning
0 Qualifications | 19 Assessment Standards (19 Units) | View Education Organisations with Consent to Assess |
Qualifications Domain-full
No qualifications currently registered at this level. Also check fields and sub-fields.
Assessment Standards
Hide education organisations, CMR & purpose »
Level 5
Commission power system equipment from 'end to end'
This standard has expired and is no longer available.
Version 4
14279 Unit Standard 7 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: prepare for commissioning tests and trial operation of power system equipment from 'end to end'; carry out commissioning 'end to end' tests and 'in-service' commissioning tests; and complete documentation and report results.
Standard-setting body:
Commission, service and/or repair communication systems between electricity supply substations
This standard has expired and is no longer available.
Version 3
14292 Unit Standard 7 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: prepare for commission, service and/or repair of communication systems between electricity supply substations; carry out tests and document results; analyse test results and complete compliance documentation; and carry out corrective action.
Standard-setting body:
Identify need and develop plans for power network reinforcement
This standard has expired and is no longer available.
Version 4
14298 Unit Standard 10 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: analyse and interpret load flow study data for identifying the need for power network reinforcement; analyse and interpret customer future power network load needs; scope and develop power network reinforcement options; evaluate and report on capacity, quality, environmental and cost features for each option; and verify report conclusions, and present report to client.
Standard-setting body:
Design power network substation electrical arrangement up to 72.5kV
This standard has expired and is no longer available.
Version 4
14299 Unit Standard 12 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: analyse and interpret a project design brief for power network substation electrical arrangement up to 72.5kV; evaluate environmental effects and design constraints; develop main electrical circuit equipment plans and capacity size the electrical equipment; carry out purchase and construction cost estimation; and verify design and present report to client.
Standard-setting body:
Design physical layout for substations up to 72.5kV
This standard has expired and is no longer available.
Version 4
14300 Unit Standard 12 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: analyse and interpret main circuit diagrams for physical layout for substations up to 72.5kV; select main equipment type, and size, to meet design requirements; develop a physical layout plan for main substation equipment; develop cable and line access route plans for substation; plan for auxiliary services and security facilities; and verify design and present drawings.
Standard-setting body:
Prepare civil and structural design specification documents for substations
This standard has expired and is no longer available.
Version 4
14303 Unit Standard 10 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: analyse and interpret station main electrical equipment physical layout plans, drawings, and design brief for civil and structural design specification documents for substations; analyse and interpret seismic and environmental safety specification equipment requirements; develop civil and structural specifications for substation above-ground main electrical and ancillary equipment and facilities; develop civil and structural specifications for substation below-ground services and foundations; and verify civil and structural design and present drawings and reports.
Standard-setting body:
Design earthing systems for substations up to 72.5kV
This standard has expired and is no longer available.
Version 4
14304 Unit Standard 10 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: analyse and interpret main circuit equipment site plans and associated design brief documents for designing earthing and bonding systems at substations up to 72.5kV; select suitable conductor size and earth matt configurations; develop detailed drawings and specification for installing earthing system; and verify design and present drawings and reports.
Standard-setting body:
Design power line installation up to 72.5kV
This standard has expired and is no longer available.
Version 4
14308 Unit Standard 10 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: analyse and interpret design brief for power line installation up to 72.5kV; design power line circuit and installation; calculate line equipment purchase and installation costs; and verify the line design and present reports and drawings.
Standard-setting body:
Conduct a line location route survey up to 72.5kV
This standard has expired and is no longer available.
Version 4
14309 Unit Standard 12 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: analyse and interpret the project brief for a line route survey, and associated maps, for conducting a line location route survey for lines up to 72.5kV; evaluate various possible line route options and develop route plans; negotiate with land owners for access rights and legal easements; develop preferred line route plan and line design parameters, and present reports to clients; and apply for territorial authority resource consent.
Standard-setting body:
Prepare civil and structural design specification documents for line and cable design
This standard has expired and is no longer available.
Version 4
14310 Unit Standard 10 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: analyse and interpret project brief, and civil and structural designs, for preparing design specification documents for line and cable design; develop civil and structural design specifications and drawings for lines; develop civil and structural design specifications and drawings for cables; and verify the design specifications and present reports and drawings.
Standard-setting body:
Design power cable installation up to 72.5kV
This standard has expired and is no longer available.
Version 4
14312 Unit Standard 15 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: analyse and interpret project design brief, associated documentation, and network drawings for the design of a power cable installation up to 72.5kV; select cable design dimensions; design cable electrical protection system; design cable support and installation requirements; select cable jointing and termination systems; and verify and present specification documents, drawings and costings for a complete cable installation.
Standard-setting body:
Level 6
Design electrical protection system for power network substation up to 72.5kV
This standard has expired and is no longer available.
Version 4
14301 Unit Standard 15 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: analyse and interpret substation main circuit plans and develop a protection design philosophy for power network substations up to 72.5kV; design protection and control systems for network supply main equipment and feeders; develop ancillary equipment protection and control system plans; and verify protection design and present drawings.
Standard-setting body:
Design power network supervisory control and data acquisition (SCADA) system
This standard has expired and is no longer available.
Version 4
14302 Unit Standard 15 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: analyse and interpret substation main equipment circuit drawings, ancillary equipment, protection and control drawings for the design of power network supervisory control and data acquisition (SCADA) system; develop supervisory control and data acquisition system for power networks; develop SCADA specifications and supporting documentation; and verify the SCADA system and present drawings and reports.
Standard-setting body:
Apply seismic design criteria to substation equipment and structural designs
This standard has expired and is no longer available.
Version 4
14305 Unit Standard 10 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: analyse and interpret substation equipment and structural designs for vulnerability to seismic activity; apply seismic design criteria to substation equipment; develop solutions for ensuring seismic safety; and verify seismic design features and present drawings and conclusions.
Standard-setting body:
Design voltage regulation system for power network
This standard has expired and is no longer available.
Version 4
14306 Unit Standard 10 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: analyse and interpret power network configuration and load variation studies for designing a voltage regulation system for power networks; design voltage regulation system; verify design and present drawings and reports; and review voltage regulation on the system as installed.
Standard-setting body:
Design load control systems for power systems up to 72.5kV
This standard has expired and is no longer available.
Version 4
14307 Unit Standard 15 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: analyse and interpret power network load flow studies and network configuration drawings for design of load control systems for power systems up to 72.5kV; design load control systems and prepare design drawings; prepare specification drawings and supporting documentation; and verify design and present drawings and specifications.
Standard-setting body:
Design line and cable earthing and insulation coordination system
This standard has expired and is no longer available.
Version 4
14311 Unit Standard 10 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: analyse and interpret the project design brief and associated line or cable documentation for designing line and cable earthing and insulation coordination system; develop design specifications for line earthing and insulation coordination; develop design specification for cable earthing and insulation coordination; and verify the design and present documentation report and drawings.
Standard-setting body:
Design metering systems for power systems up to 72.5kV
This standard has expired and is no longer available.
Version 4
14313 Unit Standard 15 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: analyse and interpret project design brief for metering systems for power systems up to 72.5kV; evaluate metering system options and solutions; design and specify a metering system and develop specifications for suitable equipment; determine instrument transformer requirements and accuracy class; and verify design and present design report and supporting drawings.
Standard-setting body:
Commission and re-commission plant in the electricity supply industry
This standard has expired and is no longer available.
Version 5
15560 Unit Standard 12 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: plan, programme, and implement, commission and re-commission of plant; and review results of commissioning and re-commissioning of plant; and conduct handover of the commissioned and re-commissioned plant.
Standard-setting body:
Data as at 2025-05-01 23:01:07.45