Conduct coal sampling in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17907 Unit Standard 1 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of coal formation, composition, and sampling equipment; sample coal in a thermal electricity generation power station; and identify and respond to deviations in the normal operation of coal sampling.
Standard-setting body:
Operate a vacuum cleaning plant in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17913 Unit Standard 1 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of a vacuum cleaning plant and controls; operate and monitor a vacuum cleaning plant in a thermal electricity generation power station; and identify and respond to deviations in the normal operation of a vacuum cleaning plant.
Standard-setting body:
Level 3
Operate nitrogen and carbon dioxide systems in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17403 Unit Standard 2 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of nitrogen and carbon dioxide systems and controls; operate and monitor nitrogen and carbon dioxide systems; and identify and respond to deviations.
Standard-setting body:
Operate soot blowing system in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17422 Unit Standard 2 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of soot blowing systems and controls; operate and monitor soot blowing systems; and identify and respond to deviations.
Standard-setting body:
Operate coal handling equipment in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 5
17905 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: demonstrate knowledge of coal handling equipment and controls; operate and monitor coal handling equipment in a thermal electricity generation power station; and identify and respond to deviations in the normal operation of coal handling equipment.
Standard-setting body:
Store coal in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17906 Unit Standard 3 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of coal storage; operate and monitor coal storage equipment in a thermal electricity generation power station; and identify and respond to deviations in the normal operation of coal storage.
Standard-setting body:
Operate a weighbridge in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17908 Unit Standard 3 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of a weighbridge and its controls; operate and monitor a weighbridge in a thermal electricity generation power station; and identify and respond to deviations in the normal operation of a weighbridge.
Standard-setting body:
Conduct ash handling in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 5
17911 Unit Standard 5 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: demonstrate knowledge of ash and ash handling equipment; operate and monitor ash handling equipment in a thermal electricity generation power station; and identify and respond to deviations in the normal operation of ash handling.
Standard-setting body:
Operate ash ponds in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17912 Unit Standard 2 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of ash ponds and the pumping station; operate and monitor ash ponds and the pumping station in a thermal electricity generation power station; and identify and respond to deviations in the normal operation of ash ponds and the pumping station.
Standard-setting body:
Level 4
Operate gas plant in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17398 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of gas plant systems; operate and monitor gas plant systems; and identify and respond to deviations in the normal operation of a gas plant.
Standard-setting body:
Operate compressed air systems in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17399 Unit Standard 4 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of compressed air and instrument air systems and controls; operate and monitor compressed air and instrument air systems; and identify and respond to deviations.
Standard-setting body:
Operate cooling water systems in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17400 Unit Standard 3 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of cooling water systems and controls; operate and monitor cooling water systems; and identify and respond to deviations.
Standard-setting body:
Operate air conditioning in a thermal power station
This standard has expired and is no longer available.
Version 4
17401 Unit Standard 3 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of air conditioning systems and controls in a thermal power station; operate and monitor air conditioning systems in a thermal power station; and identify and respond to deviations in the normal operation of air conditioning systems.
Standard-setting body:
Operate auxiliary boiler in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17402 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of auxiliary boiler and controls; operate and monitor auxiliary boiler; and identify and respond to deviations.
Standard-setting body:
Operate fuel oil systems in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17404 Unit Standard 3 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of fuel oil systems and controls; operate and monitor fuel oil systems; and identify and respond to deviations.
Standard-setting body:
Operate fixed fire protection and detection systems in a thermal electricity generation station
This standard has expired and is no longer available.
Version 4
17405 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of fire protection and detection systems and controls; operate and monitor station fire protection and detection systems; and identify and respond to deviations.
Standard-setting body:
Operate auxiliary steam systems in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17406 Unit Standard 2 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of auxiliary steam systems and controls; operate and monitor station auxiliary steam systems; and identify and respond to deviations.
Standard-setting body:
Operate station drains in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17407 Unit Standard 3 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of station drain systems and controls; operate and monitor station drain systems; and identify and respond to deviations.
Standard-setting body:
Operate water treatment systems in a thermal power station
This standard has expired and is no longer available.
Version 4
17408 Unit Standard 8 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of water treatment systems and controls in a thermal power station; operate and monitor water treatment systems in a thermal power station; and identify and respond to deviations in the normal operation of water treatment systems.
Standard-setting body:
Operate and monitor turbine steam systems in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17409 Unit Standard 12 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of turbine steam systems and controls; operate and monitor turbine steam systems; and identify and respond to deviations in the normal operations of turbine steam systems
Standard-setting body:
Operate condensers and condensate systems in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17410 Unit Standard 4 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of condenser and condensate systems and controls; operate and monitor condenser and condensate systems; and identify and respond to deviations.
Standard-setting body:
Operate feed heating systems in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17411 Unit Standard 5 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of feed heating systems and controls; operate and monitor feed heating systems; and identify and respond to deviations.
Standard-setting body:
Operate turbine oil systems in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17412 Unit Standard 5 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of turbine oil systems and controls; operate and monitor turbine oil systems; and identify and respond to deviations.
Standard-setting body:
Operate and monitor generator and associated systems in a thermal electricity generation station
This standard has expired and is no longer available.
Version 5 This unit standard was replaced by unit standard 30106.
17413 Unit Standard 15 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: demonstrate knowledge of generator and associated systems and controls; operate and monitor generator and associated systems; and identify and respond to deviations in the normal operation of turbine oil systems.
Standard-setting body:
Operate and monitor steam and water cycle chemistry in a thermal electricity generation station
This standard has expired and is no longer available.
Version 4
17414 Unit Standard 4 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of steam and water cycle chemistry and controls; operate and monitor steam and water cycle chemistry systems; and identify and respond to deviations.
Standard-setting body:
Operate turbine control fluid systems in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17415 Unit Standard 5 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of turbine control fluid systems and controls; operate and monitor turbine control fluid systems; and identify and respond to deviations.
Standard-setting body:
Operate boiler feed pump turbine in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17416 Unit Standard 5 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of boiler feed pump turbine systems and controls; operate and monitor boiler feed pump turbine systems; and identify and respond to deviations.
Standard-setting body:
Operate boiler feed pump in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17417 Unit Standard 4 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of boiler feed pump systems and controls; operate and monitor boiler feed pump systems; and identify and respond to deviations.
Standard-setting body:
Operate boiler fuel oil systems in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17418 Unit Standard 3 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of boiler fuel oil and atomising steam systems and controls; operate and monitor boiler fuel systems; and identify and respond to deviations.
Standard-setting body:
Operate boiler air and flue gas systems in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17419 Unit Standard 4 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of boiler air and flue gas systems and controls; operate and monitor boiler air and flue gas systems; and identify and respond to deviations in boiler air and flue gas systems.
Standard-setting body:
Operate boiler steam and water circuit in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17420 Unit Standard 5 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of boiler steam and water circuit systems and controls; operate and monitor boiler steam and water circuit systems; and identify and respond to deviations.
Standard-setting body:
Operate boiler fuel gas and ignition gas systems in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17421 Unit Standard 4 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of boiler fuel gas and ignition gas systems and controls; operate and monitor boiler fuel gas and ignition gas system; and identify and respond to deviations.
Standard-setting body:
Operate coal firing in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17423 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of coal firing systems and controls; operate and monitor coal firing systems; and identify and respond to deviations.
Standard-setting body:
Operate boiler electrostatic precipitators in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17424 Unit Standard 2 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of boiler electrostatic precipitators systems and controls; operate and monitor boiler electrostatic precipitators systems; and identify and respond to deviations.
Standard-setting body:
Operate boiler circulating pumps in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17425 Unit Standard 2 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of boiler circulating pumps systems and controls; operate and monitor boiler circulating pumps systems; and identify and respond to deviations.
Standard-setting body:
Operate auxiliary steam range from a thermal electricity generation control room
This standard has expired and is no longer available.
Version 5
17426 Unit Standard 2 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: demonstrate knowledge of auxiliary steam systems and controls; operate and monitor auxiliary steam controls; and identify and respond to deviations in auxiliary steam range operations.
Standard-setting body:
Operate vents and drains from a thermal electricity generation control room
This standard has expired and is no longer available.
Version 5
17429 Unit Standard 4 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: demonstrate knowledge of vent and drain controls and operation; operate and monitor vents and drains; and identify and respond to deviations in vent and drain operations.
Standard-setting body:
Operate barring gear and jacking oil systems from a thermal electricity generation control room
This standard has expired and is no longer available.
Version 5
17430 Unit Standard 3 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: demonstrate knowledge of barring gear and jacking oil systems; operate and monitor barring gear and jacking oil systems; and identify and respond to deviations in barring gear and jacking oil systems operations.
Standard-setting body:
Operate circulated cooling water systems from a thermal electricity generation control room
This standard has expired and is no longer available.
Version 4
17434 Unit Standard 8 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of circulated cooling water systems; operate and monitor cooling water system controls; and identify and respond to deviations in circulated cooling water system operations.
Standard-setting body:
Operate coal plant from control room in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17904 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of coal plant control panels; operate and monitor coal plant from control room in a thermal electricity generation power station; and identify and respond to deviations in the normal operation of the coal plant control room.
Standard-setting body:
Operate coal and ash plant electrical systems in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 4
17909 Unit Standard 5 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of coal and ash plant electrical systems and controls; operate and monitor coal and ash plant electrical systems in a thermal electricity generation power station; and identify and respond to deviations in the normal operation of coal plant electrical systems and controls.
Standard-setting body:
Operate an ash plant control room and pump house in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 5
17910 Unit Standard 5 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: demonstrate knowledge of an ash plant control room and pump house and controls; operate and monitor an ash plant control room and pump house in a thermal electricity generation power station; and identify and respond to deviations in the normal operation of an ash plant control room and pump house.
Standard-setting body:
Operate ferrous sulphate systems in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 3
20187 Unit Standard 3 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: demonstrate knowledge of ferrous sulphate systems and controls; operate and monitor ferrous sulphate systems; and identify and respond to deviations in ferrous sulphate systems; in accordance with industry requirements.
Standard-setting body:
Carry out borax nitrate dosing and rinsing in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 3
20188 Unit Standard 3 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: demonstrate knowledge of borax nitrate dosing and rinsing for passive protection; operate borax nitrate dosing systems; and identify and respond to deviations in borax nitrate systems; in accordance with industry requirements.
Standard-setting body:
Carry out condenser tube leak testing in a thermal electricity generation power station
This standard has expired and is no longer available.
Version 2
20189 Unit Standard 5 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: demonstrate knowledge of condenser tube leak testing; conduct condenser tube leak testing; and identify and respond to deviations in condenser tube leak testing; in accordance with industry requirements.
Standard-setting body:
Operate a gas turbine and associated systems for electricity generation in a thermal power station
This standard has expired and is no longer available.
Version 2
22875 Unit Standard 16 Credits
View Education Organisations with Consent to Assess »
This unit standard is for people who work in a thermal power station. People credited with this unit standard are able to: demonstrate knowledge of gas turbines; operate a gas turbine and associated systems; and demonstrate knowledge of deviations from normal conditions in operating a gas turbine and associated systems.
Standard-setting body:
Operate and monitor a generator and associated systems in a thermal power station
This standard has expired and is no longer available.
Version 2
22876 Unit Standard 8 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to demonstrate knowledge of: electrical power and energy; electromotive force (EMF) production; magnets and magnetism; direct current (DC) generation; alternating current (AC) generation; generator and associated controls in a thermal power station; and to operate and monitor the generator and associated systems.
Standard-setting body:
Demonstrate knowledge of steam generation water treatment in a thermal power station
This standard has expired and is no longer available.
Version 2
22877 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to demonstrate knowledge of: impurities contained in water sourced for steam generator feedwater applications; processes utilised to neutralise or remove potential feedwater impurities; steam generator water quality monitoring methods and associated equipment; and the effects of steam and water cycle chemical parameter excursions.
Standard-setting body:
Operate and monitor a hydrogen cooled generator and systems in a thermal power station
This standard has expired and is no longer available.
Version 2
22878 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of hydrogen cooled generator associated systems and controls; operate and monitor hydrogen cooled generator and associated systems; and identify and respond to deviations in the normal operation of a hydrogen cooled generator and associated systems.
Standard-setting body:
Operate heat recovery steam generator (HRSG) in a thermal power station
This standard has expired and is no longer available.
Version 2
22879 Unit Standard 12 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: demonstrate knowledge of HRSG systems and controls; operate and monitor HRSGs and systems; and identify and respond to deviations during routine operation of an HRSG.
Standard-setting body:
Level 5
Operate steam raising equipment from a thermal electricity generation control room
This standard has expired and is no longer available.
Version 4
17428 Unit Standard 7 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of thermodynamics and steam raising; carry out steam raising procedure; and identify and respond to deviations in steam raising equipment operations.
Standard-setting body:
Operate condensers and vacuum raising equipment from a thermal electricity generation control room
This standard has expired and is no longer available.
Version 4
17431 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of condensers and vacuum raising systems; operate and monitor condensers and vacuum raising systems; and identify and respond to deviations in condensers and vacuum raising equipment operations.
Standard-setting body:
Operate control oil systems and steam admission valves from a thermal generation control room
This standard has expired and is no longer available.
Version 4
17432 Unit Standard 8 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of control oil systems and steam admission valves; operate and monitor control oil systems and steam admission valves; and identify and respond to deviations in control oil systems and steam admission valve operations.
Standard-setting body:
Operate boiler and steam generator draught systems from a thermal generation control room
This standard has expired and is no longer available.
Version 4
17435 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of draught systems; operate and monitor fans and purging controls; and identify and respond to deviations in boiler and steam generator draught system operations.
Standard-setting body:
Operate electric feed pumps from a thermal electricity generation control room
This standard has expired and is no longer available.
Version 4
17436 Unit Standard 4 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of electric feed pumps; operate and monitor electric feed pumps; and identify and respond to deviations in electric feed pump operation.
Standard-setting body:
Operate plant control electrical systems from a thermal electricity generation control room
This standard has expired and is no longer available.
Version 4
17437 Unit Standard 4 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of panel electrical systems and controls; control and operate panel electrical systems; and identify and respond to deviations in plant control electrical system operations.
Standard-setting body:
Operate feed heating systems from a thermal electricity generation control room
This standard has expired and is no longer available.
Version 4
17439 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of feed heater systems; operate and monitor feed heater systems; and identify and respond to deviations in feed heater operations.
Standard-setting body:
Operate gas firing controls from a thermal electricity generation control room
This standard has expired and is no longer available.
Version 4
17440 Unit Standard 4 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of gas firing equipment and controls; operate and monitor gas firing equipment; and identify and respond to deviations in gas firing operations.
Standard-setting body:
Operate generator cooling and seal oil systems from a thermal electricity generation control room
This standard has expired and is no longer available.
Version 4
17441 Unit Standard 5 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of generator cooling and seal systems; operate and monitor generator cooling and seal systems; and identify and respond to deviations in generator cooling and seal oil system operations.
Standard-setting body:
Operate gland steam systems from a thermal electricity generation control room
This standard has expired and is no longer available.
Version 4
17442 Unit Standard 3 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of gland steam systems; operate and monitor gland steam systems; and identify and respond to deviations in gland steam system operations.
Standard-setting body:
Operate lube oil systems from a thermal electricity generation control room
This standard has expired and is no longer available.
Version 4
17443 Unit Standard 5 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of lube oil systems; operate and monitor lube oil systems; and identify and respond to deviations in lube oil system operations.
Standard-setting body:
Monitor and carry out routine operations from a thermal electricity generation control room
This standard has expired and is no longer available.
Version 4
17445 Unit Standard 4 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of panel monitoring and routine operations; monitor and carry out routine operations on thermal plant control panel; and identify and respond to deviations in routine operations.
Standard-setting body:
Control and monitor chemistry conditions from a thermal electricity generation control room
This standard has expired and is no longer available.
Version 4
17446 Unit Standard 5 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of plant chemistry; operate and monitor operation of a mixed bed unit and chemical dosing systems; and identify and respond to deviations in chemistry conditions.
Standard-setting body:
Operate during plant trips from a thermal electricity generation control room
This standard has expired and is no longer available.
Version 4
17447 Unit Standard 5 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of plant runbacks and trips and operate and monitor plant during unplanned events and trips.
Standard-setting body:
Monitor turbine supervisory from a thermal electricity generation control room
This standard has expired and is no longer available.
Version 4
17448 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of turbine supervisory; operate and monitor operation of turbine supervisory equipment; and identify and respond to deviations in turbine supervisory operations.
Standard-setting body:
Carry out on load valve tests and simulated trip tests on thermal electricity generation plant
This standard has expired and is no longer available.
Version 4
17449 Unit Standard 3 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of the on load valve tests and simulated trip tests; operate and monitor on load valve tests and simulated trip tests; and identify and respond to deviations during on load valve tests and simulated trip tests.
Standard-setting body:
Level 6
Carry out a controlled start up of thermal electricity generation plant
This standard has expired and is no longer available.
Version 4
17427 Unit Standard 15 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of thermal plant start up; operate and monitor a thermal plant start up; and identify and respond to deviations in a thermal plant start up.
Standard-setting body:
Carry out controlled shutdown of thermal electricity generation plant
This standard has expired and is no longer available.
Version 4
17433 Unit Standard 10 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of thermal plant shutdowns; operate and monitor plant during a unit shutdown; and identify and respond to deviations in a controlled shutdown.
Standard-setting body:
Excite and synchronise thermal electricity generation plant
This standard has expired and is no longer available.
Version 4
17438 Unit Standard 5 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to: demonstrate knowledge of excitation and synchronising; operate and monitor excitation and synchronising equipment; and identify and respond to deviations in excitation and synchronising equipment operations.
Standard-setting body:
Operate panel controls from a thermal electricity generation control room
This standard has expired and is no longer available.
Version 4
17444 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this standard are able to demonstrate knowledge of panel controls and operate panel controls.