Domain - Suspended Scaffolding

Domain - Suspended Scaffolding

Search Standards

All unit standards registered on the Directory of Assessment Standards may be accessed here. 

TOP > Service Sector > Lifting Equipment > Suspended Scaffolding

Qualifications Domain-full

No qualifications currently registered at this level. Also check fields and sub-fields.

Assessment Standards

Hide education organisations, CMR & purpose  »

Level 3

Handle and maintain suspended scaffolding components

Word  PDF

Version 4 This unit standard, unit standard 26592, unit standard 26593 and unit standard 26594 replaced unit standard 4204, unit standard 4205, and unit standard 4207.

26591 Unit Standard 5 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - identify suspended scaffolding components; - handle suspended scaffolding components safely; and - perform routine maintenance tasks on suspended scaffolding components.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Plan and prepare for the erection of proprietary suspended scaffolding

Word  PDF

Version 5 This unit standard, unit standard 26591, unit standard 26593, and unit standard 26594 replaced unit standard 4204, unit standard 4205, and unit standard 4207.

26592 Unit Standard 10 Credits

View Education Organisations with Consent to Assess  »

This unit standard is intended to cover the planning and preparation for erecting a suspended scaffold until work begins on-site. People credited with this unit standard are able to: - determine the purpose and loads, and confirm the parameters of, suspended scaffolds prior to erection; - notify a suspended scaffold prior to erection; - identify on-site hazards associated with the erection of suspended scaffolds and complete company safety documentation; - sketch plans for the erection of suspended scaffolds; and - compile equipment list and schedule equipment necessary for the erection of suspended scaffolds.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Complete suspended scaffolding inspection compliance reports

Word  PDF

Version 5 This unit standard replaced unit standard 4206.

26595 Unit Standard 4 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to complete suspended scaffolding inspection compliance reports for a boatswain''s chair and a swinging stage.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Explain legislative requirements that apply to the design of suspended scaffolding

Word  PDF

Version 5

26607 Unit Standard 3 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - complete and process suspended scaffolding industry forms; - describe legislative requirements that apply to suspended scaffolding design; - explain requirements that relate to edge protection; - explain legislative requirements and manufacturers'' operating instructions that relate to suspended scaffolding systems; and - explain legislative requirements that apply to the inspection of suspended scaffolding equipment.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Induct users in the operation and inspection of suspended scaffolds

Word  PDF

Version 1

32878 Unit Standard 5 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: . induct users in the safe use of suspended scaffolds; . induct users in the emergency procedures for suspended scaffolds; . induct users to complete daily suspended scaffold checks, explain the load test and check that the user induction procedures are conducted; . complete induction documentation to ensure the user understands safe operation, daily check procedures and the handover certificate procedures.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Level 4

Erect, operate, and dismantle boatswain's chairs

Word  PDF

Version 5 This unit standard, unit standard 26591, unit standard 26592, and unit standard 26594 replaced unit standard 4204, unit standard 4205, and unit standard 4207.

26593 Unit Standard 5 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - plan and prepare for the suspension of boatswain''s chairs; - erect overhead structures and associated safety systems for the suspension of boatswain''s chairs; - assemble and suspend boatswain''s chair and associated safety systems from suspension point(s) on overhead scaffolding; - check the structure is compliant and complete the GPG inspection report; - operate boatswain''s chairs; and - dismantle boatswain''s chairs.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Erect, operate, and dismantle swinging stages

Word  PDF

Version 5 This unit standard, unit standard 26591, unit standard 26592, and unit standard 26593 replaced unit standard 4204, unit standard 4205, and unit standard 4207.

26594 Unit Standard 10 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - plan and prepare for the suspension of swinging stages; - erect overhead structures and associated safety systems for the suspension of swinging stages; - assemble and suspend swinging stages and associated safety systems from suspension points on overhead scaffolding; - check the structure is compliant and complete the GPG inspection report; - operate swinging stages; and - dismantle swinging stages.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Data as at 2024-04-19 23:01:07.723