Level 2

Handle and maintain basic scaffolding components

Word  PDF

Version 6 This unit standard, unit standard 20856, and unit standard 23228 replaced unit standard 4200 and unit standard 4202.

20855 Unit Standard 5 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - identify basic scaffolding components; - handle basic scaffolding components safely; and - perform routine maintenance tasks on basic scaffolding components.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Level 3

Demonstrate knowledge of the erection and dismantling of scaffolding up to five metres in height

Word  PDF

Version 6 This unit standard and unit standard 13053 replaced unit standard 617.

13016 Unit Standard 3 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - demonstrate knowledge of the erection, alteration, maintenance, inspection, and dismantling of scaffolding up to five metres in height; . describe the procedures for erecting scaffolding up to five metres in height; and . describe the procedures for dismantling scaffolding up to five metres in height.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Erect and dismantle scaffolding up to five metres in height

Word  PDF

Version 6 This unit standard and unit standard 13016 replaced unit standard 617.

13053 Unit Standard 6 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: erect, alter, inspect, and dismantle scaffolding up to five metres in height; and complete work operations on site.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Interpret and apply health and safety legislative requirements to scaffolding work

Word  PDF

Version 6

19620 Unit Standard 3 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - explain the legislative requirements for scaffolding in the Health and Safety at Work Act 2015; - complete scaffolding industry health and safety risk management documentation; - demonstrate knowledge of personal protective equipment (PPE) in the scaffolding industry; - interpret legislative requirements that relate to public protection in the scaffolding industry; and - interpret and apply health and safety legislative requirements to the inspection of scaffolding equipment.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Interpret and apply legislative requirements in the design of scaffolding works

Word  PDF

Version 6

19621 Unit Standard 3 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - complete and process scaffolding industry forms; . demonstrate knowledge of legislative requirements that relate to scaffold design; . explain legislative requirements that relate to different scaffolding types; . explain the legislative requirements and manufacturer instructions for scaffolding systems; . explain legislative requirements that relate to edge protection; . explain and apply legislative requirements to scaffolds over verandahs, gantries and rooves, and scaffolding accessories; and . explain and apply legislative requirements to inspection of scaffolding equipment.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Use and maintain scaffolding hand and portable power tools

Word  PDF

Version 6

19622 Unit Standard 2 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: . select and use hand tools for scaffolding; . care for and identify faulty hand tools; . select and use portable power tools for scaffolding; . describe procedures, and care for and maintain portable power tools; and . use hand and power tools safely.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Use tube and coupler in standing proprietary scaffolds

Word  PDF

Version 6

19623 Unit Standard 6 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to use tube and coupler to: create ties, rakers, guardrails and midrails; link towers; and provide additional bracing, in standing proprietary scaffolds.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Plan and prepare for the erection of scaffolding

Word  PDF

Version 7 This unit standard, unit standard 20855, and unit standard 23228 replaced unit standard 4200 and unit standard 4202.

20856 Unit Standard 5 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - confirm the purpose, duty load and parameters of the scaffold to be erected; - notify the scaffold to be erected; - identify on-site hazards associated with the erection of the proposed scaffold and complete the required safety documentation; - sketch plans for the erection of the proposed scaffold; and - assess and schedule the transport of equipment necessary for the erection of the scaffold.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Prepare a scaffolding site for the basing out of scaffolding

Word  PDF

Version 6 This unit standard, unit standard 20858, unit standard 20859, unit standard 20860, unit standard 23223, unit standard 23224, unit standard 23225, unit standard 23226, and unit standard 23227 replaced unit standard 4201 and unit standard 4203.

20857 Unit Standard 5 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - confirm the conditions for the erection of a scaffold on site; - secure the site work area for the erection of a scaffold; - establish the start point for the erection of a scaffold on site; and - lay out equipment on site for the basing out of a scaffold.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Base out tube and coupler scaffolding

Word  PDF

Version 7 This unit standard, unit standard 20857, unit standard 20859, unit standard 20860, unit standard 23223, unit standard 23224, unit standard 23225, unit standard 23226, and unit standard 23227 replaced unit standard 4201 and unit standard 4203.

20858 Unit Standard 10 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - position and stand standards for tube and coupler scaffolding; - position and attach ledgers, braces, transoms and putlogs for tube and coupler scaffolding; - fit planks for tube and coupler scaffolding; and - check that the structure is compliant.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Base out proprietary frame scaffolding

Word  PDF

Version 7 This unit standard, unit standard 20857, unit standard 20858, unit standard 20860, unit standard 23223, unit standard 23224, unit standard 23225, unit standard 23226, and unit standard 23227 replaced unit standard 4201 and unit standard 4203.

20859 Unit Standard 4 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: . position and stand frames for multiple-bay for proprietary frame scaffolds; - install and identify situations for the bracing of proprietary frame scaffolds; . install working platforms for proprietary frame scaffolds. - check that the structure is compliant.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Base out individual component proprietary scaffolding

Word  PDF

Version 7 This unit standard, unit standard 20857, unit standard 20858, unit standard 20859, unit standard 23223, unit standard 23224, unit standard 23225, unit standard 23226, and unit standard 23227 replaced unit standard 4201 and unit standard 4203.

20860 Unit Standard 6 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - position and stand standards for individual component proprietary scaffolding; - position and attach ledgers, transoms, and braces for individual component proprietary scaffolding; - fit and secure platform components for individual component proprietary scaffolding; and - check that the structure is compliant.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Base out returns for tube and coupler scaffolding

Word  PDF

Version 5 This unit standard, unit standard 20857, unit standard 20858, unit standard 20859, unit standard 20860, unit standard 23224, unit standard 23225, unit standard 23226 and unit standard 23227 replaced unit standard 4201 and unit standard 4203.

23223 Unit Standard 8 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to, when basing out returns using tube and coupler scaffolding: - position and stand standards; - position and attach ledgers, bracing, transoms and putlogs; - fit planks; and - check the structure is compliant and complete the GPG inspection report.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Erect and dismantle standing tube and coupler scaffolding

Word  PDF

Version 5 This unit standard, unit standard 20857, unit standard 20858, unit standard 20859, unit standard 20860, unit standard 23223, unit standard 23225, unit standard 23226 and unit standard 23227 replaced unit standard 4201 and unit standard 4203.

23224 Unit Standard 10 Credits

View Education Organisations with Consent to Assess  »

In the context of erecting and dismantling tube and coupler scaffolding, people credited with this unit standard are able to: - establish a safe area on the next working lift; - build the working lift; . check the structure is compliant and complete the GPG inspection report; . ready the lift above; and . dismantle tube and coupler scaffolding.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Erect and dismantle mobile scaffolding

Word  PDF

Version 5 This unit standard, unit standard 20857, unit standard 20858, unit standard 20859, unit standard 20860, unit standard 23223, unit standard 23224, unit standard 23226 and unit standard 23227 replaced unit standard 4201 and unit standard 4203.

23225 Unit Standard 4 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: . check the stability of mobile scaffolding; - establish a safe area on the next working lift; . build the working lift; - check the structure is compliant and complete the GPG inspection report; - ready the lift above; and . dismantle mobile scaffolding.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Erect and dismantle proprietary falsework

Word  PDF

Version 5 This unit standard, unit standard 20857, unit standard 20858, unit standard 20859, unit standard 20860, unit standard 23223, unit standard 23224, unit standard 23225 and unit standard 23227 replaced unit standard 4201 and unit standard 4203.

23226 Unit Standard 4 Credits

View Education Organisations with Consent to Assess  »

This unit standard covers proprietary falsework where the load weight has been determined by others in accordance with the Good Practice Guidelines. People credited with this unit standard are able to: . confirm the load to be supported by proprietary falsework; . base out proprietary falsework; . ready proprietary falsework for the next lift; . complete the second level of proprietary falsework; . check the structure is compliant and complete the GPG inspection report; and . dismantle proprietary falsework.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Erect and dismantle standing proprietary scaffolding

Word  PDF

Version 5 This unit standard, unit standard 20857, unit standard 20858, unit standard 20859, unit standard 20860, unit standard 23223, unit standard 23224, unit standard 23225 and unit standard 23226 replaced unit standard 4201 and unit standard 4203.

23227 Unit Standard 6 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to, for both proprietary frame scaffolding and individual component proprietary systems: . install working platforms; . follow operational procedures while erecting subsequent components; . check the structure is compliant and complete the GPG inspection report; and . dismantle proprietary scaffolding.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Complete a scaffolding inspection compliance report

Word  PDF

Version 5 This unit standard, unit standard 20855 and unit standard 20856 replaced unit standard 4200 and unit standard 4202.

23228 Unit Standard 4 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - complete an inspection compliance report for tube and coupler scaffolding; and - complete an inspection compliance report for proprietary scaffolding.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Demonstrate and apply knowledge of leadership skills and communicate instructions on a scaffolding worksite

Word  PDF

Version 3

30628 Unit Standard 3 Credits

View Education Organisations with Consent to Assess  »

This unit standard is for people who work in the scaffolding industry. People credited with this unit standard are able to: - demonstrate knowledge of the role of a scaffolding team leader; - communicate instructions to a group of scaffolding workers; and - demonstrate leadership skills with a group of scaffolding workers.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Erect, dismantle and inspect non-notifiable prefabricated frame scaffolding up to five metres in height

Word  PDF

Version 8

9184 Unit Standard 5 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - demonstrate knowledge of non-notifiable prefabricated frame scaffolding; - undertake and implement a task analysis for the erection, use and dismantling of non-notifiable prefabricated frame scaffolding up to five metres in height; . erect and inspect non-notifiable prefabricated frame scaffolding up to five metres in height; . alter non-notifiable prefabricated frame scaffolding up to five metres in height; . inspect completed non-notifiable prefabricated frame scaffolding up to five metres in height; and . dismantle completed non-notifiable prefabricated frame scaffolding up to five metres in height.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Level 4

Design, erect, and dismantle scaffolding ties

Word  PDF

Version 5

23715 Unit Standard 6 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: . demonstrate knowledge of scaffolding ties and their use; . design ties as part of scaffold plans; . erect ties and complete GPG inspection reports; and . dismantle scaffolding ties and repair attachment points.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Data as at 2024-04-26 23:01:12.72