Domain - Electricity Supply - Live Work
TOP > Engineering and Technology > Electricity Supply > Electricity Supply - Live Work
0 Qualifications | 28 Assessment Standards (28 Units) | View Education Organisations with Consent to Assess |
Qualifications Domain-full
No qualifications currently registered at this level. Also check fields and sub-fields.
Assessment Standards
Hide education organisations, CMR & purpose »
Level 3
Carry out short-term inspections of electricity network structures up to line voltage live line MAD
This standard has expired and is no longer available.
Version 4
17570 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: identify electricity network systems; carry out pre-climbing safety checks on electricity network structures; select electricity network structure climbing equipment; use electricity network structure climbing equipment; carry out above ground inspection on electricity network structures; and document inspection on electricity network structures up to live line MAD.
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Prepare working zone for applying protective coatings to tower steel within MAD
This standard has expired and is no longer available.
Version 3
17572 Unit Standard 4 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: determine condition of steel in work area and the surface protection to be applied; establish work sites; wash insulators on electricity structures; move jumpers and insulator strings on electricity structures; and document protective coating work on electricity structures.
Standard-setting body:
Level 4
Remove and install line hardware and equipment on structures using live line hot stick up to 66kV
Version 6
10531 Unit Standard 20 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to remove and install line hardware and equipment using live line hot stick up to 66kV.
Consent & Moderation Requirements:
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Remove and install hardware on termination towers using hot sticks greater than 110kV
This standard has expired and is no longer available.
Version 5
10532 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: plan and prepare for live line hot stick work greater than 110kV on termination towers; displace and reinstate conductors on termination towers using live line hot sticks greater than 110kV; replace tower components on termination towers using live line hot sticks greater than 110kV; and report work on the removal and installation of termination tower hardware on pole structures using live line hot sticks greater than 110kV.
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Remove and install line hardware on angle towers using live line hot sticks greater than 110kV
This standard has expired and is no longer available.
Version 5
10533 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: plan and prepare for live line hot stick work greater than 110kV on angle towers; displace and reinstate conductors on angle towers using live line hot sticks greater than 110kV; replace tower components on angle towers using live line hot sticks greater than 110kV; and report work on the removal and installation of angle tower hardware on pole structures using live line hot sticks greater than 110kV.
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Remove and install line hardware on suspension towers using live line hot sticks greater than 110kV
This standard has expired and is no longer available.
Version 5
10534 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: plan and prepare for live line hot stick work greater than 110kV on suspension towers; displace and reinstate conductors on suspension towers using live line hot sticks greater than 110kV; replace tower components on suspension towers using live line hot sticks greater than 110kV; and report work on the removal and installation of suspension tower hardware on pole structures using live line hot sticks greater than 110kV.
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Remove and install electricity network pole structures using live line hot stick up to 66kV
Version 6
10535 Unit Standard 20 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to remove and install electricity network pole structures using live line hot stick up to 66kV.
Consent & Moderation Requirements:
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Make and break high voltage connections up to 33kV using live line hot stick procedures
Version 6
10536 Unit Standard 10 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to make and break high voltage connections up to 33kV using live line hot stick procedures.
Consent & Moderation Requirements:
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Make and break high voltage connections up to 33kV using live line glove and barrier procedures
Version 6
10537 Unit Standard 10 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to make and break high voltage connections up to 33kV using live line glove and barrier procedures.
Consent & Moderation Requirements:
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Inspect, test, and clean live line tools and equipment
Version 6
10538 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to inspect, clean, and test live line tools and equipment.
Consent & Moderation Requirements:
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Access electricity supply lines for bare-hand live line work
This standard has expired and is no longer available.
Version 5
10539 Unit Standard 4 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: plan and prepare to access electricity supply lines for bare-hand live line work; identify equipment for access method to be used, complete final access planning, and prepare tools; install and use tooling and rigging on structure to access conductor; and access live line conductors.
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Demonstrate knowledge of live line theory and procedures
Version 7
10542 Unit Standard 10 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to demonstrate knowledge of: live line theory, techniques, practices and asset owner approval; and how to take out live work permits.
Consent & Moderation Requirements:
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Repair and replace mid-span joints on live electricity network transmission lines
This standard has expired and is no longer available.
Version 3
17571 Unit Standard 12 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: analyse mid-span conductor condition and prepare to repair and replace mid-span conductors; establish mid-span conductor work site; repair and replace mid-span conductors; and document mid-span conductor work.
Standard-setting body:
Remove and install electricity network hardware on termination towers using bare hand above 50kV
This standard has expired and is no longer available.
Version 3
18034 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: plan and prepare for live line bare hand work greater than 50kV on termination towers; displace and reinstate conductors above 50kV on termination towers using bare hand; replace tower components on termination towers above 50kV using bare hand; and report work on the removal and installation of electricity network hardware on termination towers using bare hand above 50kV.
Standard-setting body:
Remove and install electricity network hardware on angle towers using bare hand greater than 50kV
This standard has expired and is no longer available.
Version 3
18035 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: plan and prepare for live line bare hand work greater than 50kV on angle towers; displace and reinstate conductors above 50kV on angle towers using bare hand; replace tower components on angle towers above 50kV using bare hand; and report work on the removal and installation of electricity network hardware on termination towers using bare hand above 50kV.
Standard-setting body:
Remove and install electricity network hardware on suspension towers using bare hand above 50kV
This standard has expired and is no longer available.
Version 3
18036 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: plan and prepare for live line bare hand work greater than 50kV on suspension towers; displace and reinstate conductors above 50kV on suspension towers using bare hand; replace tower components on suspension towers above 50kV using bare hand; and report work on the removal and installation of electricity network hardware on suspension towers using bare hand above 50kV.
Standard-setting body:
Joint live low voltage polymeric insulated power cables in the electricity supply industry
Version 5
20071 Unit Standard 10 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to joint live low voltage polymeric insulated power cables in the electricity supply industry.
Consent & Moderation Requirements:
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Terminate live low voltage polymeric insulated power cables in the electricity supply industry
Version 5
20072 Unit Standard 10 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to terminate live low voltage polymeric insulated power cables in the electricity supply industry.
Consent & Moderation Requirements:
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Replace and install hardware on live low voltage structures
Version 1
31956 Unit Standard 10 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to replace and install hardware on live low voltage structures.
Consent & Moderation Requirements:
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Level 5
Replace and install hardware on structures using live line glove and barrier procedures up to 33kV
Version 6
10540 Unit Standard 30 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to replace and install hardware on structures using live line glove and barrier procedures up to 33kV.
Consent & Moderation Requirements:
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Remove and install pole structures using live line glove and barrier procedures up to 33kV
Version 6
10541 Unit Standard 20 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to remove and install pole structures using live line glove and barrier procedures up to 33kV.
Consent & Moderation Requirements:
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Install non load bearing accessories on electricity supply conductors using hot stick techniques
This standard has expired and is no longer available.
Version 3
20083 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: plan and prepare for live line hot stick work on electricity supply transmission lines; install non load bearing accessories on electricity supply conductors using hot stick live line techniques; and report work on the installation of non load bearing accessories.
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Displace jumpers and suspension strings on electricity supply transmission lines using hot stick techniques
This standard has expired and is no longer available.
Version 3
20084 Unit Standard 6 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: prepare to push out jumpers and suspension strings using live line hot stick techniques on electricity supply transmission lines; displace conductors on suspension strings; and report displacement work.
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Install non load bearing accessories on electricity supply conductors using bare-hand techniques
This standard has expired and is no longer available.
Version 3
20085 Unit Standard 10 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: plan and prepare for live line bare-hand work on electricity supply transmission lines; install non load bearing accessories on electricity supply conductors using bare-hand live line techniques; and report work on the installation of non load bearing accessories.
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Replace suspension insulators on electricity supply structures using live line bare-hand techniques
This standard has expired and is no longer available.
Version 3
20086 Unit Standard 12 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: plan and prepare for replacement of suspension insulators using live line bare-hand methods; replace suspension insulators using live line bare-hand techniques; and report work on the replacement of suspension insulators.
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Replace tension insulators on electricity supply structures using live line bare-hand techniques
This standard has expired and is no longer available.
Version 3
20087 Unit Standard 15 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: plan and prepare for replacement of tension insulators using live line bare-hand techniques; replace tension insulators on electricity supply structures using live line bare-hand techniques; report work on the replacement of tension insulators.
Standard-setting body:
Waihanga Ara Rau Construction and Infrastructure Workforce Development Council
Replace electricity supply structures and cross arms using live work techniques
This standard has expired and is no longer available.
Version 2
20088 Unit Standard 12 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: plan and prepare to replace electricity supply structures and cross arms using live work techniques; establish work site to replace electricity supply structures and cross arms using live work techniques; replace electricity supply structures and cross arms using live work techniques; reinstate work site; and report structure and cross arm replacement work in accordance with industry requirements.
Standard-setting body:
Use a conductor trolley on live electricity supply conductors
This standard has expired and is no longer available.
Version 2
20089 Unit Standard 15 Credits
View Education Organisations with Consent to Assess »
People credited with this unit standard are able to: plan the use of a conductor trolley in a live environment; place and remove trolley; pass trolley through or around suspension insulator; and report work on use of conductor trolleys on live conductors in accordance with industry requirements.
Standard-setting body:
Data as at 01 November 2024