Domain - Industrial Measurement and Control - Maintenance

Domain - Industrial Measurement and Control - Maintenance

Search Standards

All unit standards registered on the Directory of Assessment Standards may be accessed here. 

TOP > Engineering and Technology > Industrial Measurement and Control > Industrial Measurement and Control - Maintenance

Qualifications Domain-full

No qualifications currently registered at this level. Also check fields and sub-fields.

Assessment Standards

Hide education organisations, CMR & purpose  »

Level 3

Maintain level measurement devices used in industry

Word  PDF

Version 7

2633 Unit Standard 10 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - reconfigure or calibrate a pressure measurement device used for level measurement; - calibrate or reconfigure a level measurement system; and - service level measurement devices.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Maintain flow measurement devices used in industry

Word  PDF

Version 7

2637 Unit Standard 10 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - calibrate or configure flow measurement transmitters and devices; and - service flow measurement transmitters and devices.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Maintain control valve actuators and positioners

Word  PDF

Version 7

2640 Unit Standard 5 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - stroke-check control valve actuators and calibrate positioners; and - service control valve actuators and positioners.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Maintain signal conditioning equipment, recorder, and alarm module
This standard has expired and is no longer available.

Version 6 This unit standard and unit standard 2656 have been replaced by unit standard 24884.

2651 Unit Standard 6 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: calibrate signal conditioning equipment and a recorder; and maintain signal conditioning equipment and an alarm module.

Standard-setting body:

Te Pūkenga - New Zealand Institute of Skills and Technology

Maintain hydraulic or electro-hydraulic equipment

Word  PDF

Version 7

2664 Unit Standard 3 Credits

View Education Organisations with Consent to Assess  »

This unit standard covers installation and maintenance of hydraulic equipment used in industrial process control applications. This knowledge may for example, be used in the commissioning of hydraulic equipment connected to a programmable logic controller. People credited with this unit standard are able to: - install hydraulic or electro-hydraulic equipment; - test and calibrate hydraulic or electro-hydraulic equipment; and - service hydraulic or electro-hydraulic equipment.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Install and service pneumatic or electro-pneumatic equipment

Word  PDF

Version 7

2667 Unit Standard 5 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - install pneumatic or electro-pneumatic equipment; - test pneumatic or electro-pneumatic equipment; and - service pneumatic or electro-pneumatic equipment.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Level 4

Maintain conditioning modules and electronic or microprocessor based controllers

Word  PDF

Version 3 This unit standard replaced unit standard 2651 and unit standard 2656.

24884 Unit Standard 6 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - reconfigure or calibrate signal conditioning modules; - configure and test an electronic or microprocessor based controller; - service signal conditioning modules; and - service an electronic or microprocessor based controller.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Maintain pressure measurement devices

Word  PDF

Version 7

2631 Unit Standard 10 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - reconfigure or calibrate pressure measurement devices; and - service and test pressure measurement devices and systems.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Maintain temperature measurement devices used in industry

Word  PDF

Version 7

2635 Unit Standard 10 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - reconfigure or calibrate temperature measurement devices; - service and test temperature measurement devices and systems.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Maintain and service control valves in accordance with industry requirements

Word  PDF

Version 7

2639 Unit Standard 10 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: maintain and service control valves in accordance with industry requirements.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Maintain a pH measuring system for chemical analysis

Word  PDF

Version 7

2642 Unit Standard 4 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - calibrate a pH measuring system in accordance with industry requirements; and - verify operation of pH measuring system is correct and service in accordance with industry requirements.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Maintain a conductivity measuring system

Word  PDF

Version 7

2643 Unit Standard 4 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - calibrate a conductivity measuring system in accordance with industry requirements; and - service a conductivity measuring system in accordance with industry requirements.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Maintain a dissolved oxygen measuring system

Word  PDF

Version 7

2644 Unit Standard 4 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - calibrate a dissolved oxygen measuring system; and - maintain and service a dissolved oxygen measuring system.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Maintain a consistency or a viscosity measuring system

Word  PDF

Version 7

2645 Unit Standard 4 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - calibrate a consistency or a viscosity measuring system; and - maintain operation of and service a consistency or a viscosity measuring system.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Maintain analytical monitoring equipment

Word  PDF

Version 7

2646 Unit Standard 4 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - calibrate analytical exhaust monitoring equipment; and - service analytical exhaust monitoring equipment.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Maintain humidity or dewpoint monitoring equipment

Word  PDF

Version 7

2647 Unit Standard 4 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - calibrate humidity or dewpoint monitoring equipment; and - maintain and repair humidity or dewpoint monitoring equipment.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Maintain and calibrate density monitoring equipment

Word  PDF

Version 7

2648 Unit Standard 4 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - calibrate density measuring devices; and - maintain density measuring devices.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Maintain smart instruments and loops used in industry
This standard has expired and is no longer available.

Version 6

2652 Unit Standard 2 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to calibrate and maintain smart instruments and loops used in industry.

Standard-setting body:

Te Pūkenga - New Zealand Institute of Skills and Technology

Maintain electronic or microprocessor based controllers
This standard has expired and is no longer available.

Version 6 This unit standard and unit standard 2651 have been replaced by unit standard 24884.

2656 Unit Standard 2 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to calibrate, and maintain and repair an electronic or microprocessor based controller.

Standard-setting body:

Te Pūkenga - New Zealand Institute of Skills and Technology

Maintain pneumatic controllers

Word  PDF

Version 7

2657 Unit Standard 5 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - calibrate a pneumatic controller; and - maintain and repair a pneumatic controller.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Maintain chromatographs

Word  PDF

Version 7

4356 Unit Standard 4 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - calibrate chromatographs; and - maintain and repair chromatographs.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Tune or adjust a plant control loop

Word  PDF

Version 7

4357 Unit Standard 2 Credits

View Education Organisations with Consent to Assess  »

This unit standard covers tuning and adjustment of plant control loops and complements Unit 2655, Tune control loops, and proves competence in tuning or adjusting a real plant control loop. People credited with this unit standard are able to: - tune or adjust a plant control loop.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Level 5

Demonstrate knowledge of the operation, measurement, and control of an industrial process

Word  PDF

Version 3

19233 Unit Standard 10 Credits

View Education Organisations with Consent to Assess  »

This unit standard is intended for use in the training and assessment of industrial measurement and control. Candidates who have achieved this unit standard can apply their knowledge in a practical application. People credited with this unit standard are able to demonstrate and apply knowledge of the: - operation of an industrial process; and - measurement and control of an industrial process.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Diagnose and correct faults in industrial measurement and control systems

Word  PDF

Version 4

19234 Unit Standard 10 Credits

View Education Organisations with Consent to Assess  »

People credited with this unit standard are able to: - describe common faults in measurement and control systems; - perform initial assessment of fault symptoms; - minimise consequences of fault and repair procedures in measurement and control systems; - locate and correct faults in measurement and control systems; and - update plant records for measurement and control systems following fault correction.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Maintain and manage specialist analytical equipment used in industrial processes

Word  PDF

Version 3

19235 Unit Standard 10 Credits

View Education Organisations with Consent to Assess  »

This unit standard is intended for use in the training and assessment of industrial measurement and control. It covers maintenance and management of specialist analytical equipment such as spectrophotometers, mass spectrometers, chemiluminescence analysers, and chromatographs, or analytical equipment of similar complexity. People credited with this unit standard are able to: - calibrate specialist analytical equipment; - specify and maintain sample processing system associated with specialist analytical equipment; - diagnose and correct faults in specialist analytical equipment; - carry out routine maintenance procedures on specialist analytical equipment; and - manage maintenance of specialist analytical equipment.

Consent & Moderation Requirements:

CMR 3 Word PDF

Standard-setting body:

Waihanga Ara Rau Construction and Infrastructure Workforce Development Council

Configure, test, and commission a distributed control system
This standard has expired and is no longer available.

Version 2

19236 Unit Standard 10 Credits

View Education Organisations with Consent to Assess  »

This unit standard is intended for use in the training and assessment of industrial measurement and control technicians beyond the knowledge and skills included in the National Certificate in Industrial Measurement and Control (Level 4) [Ref: 0410]. People credited with this unit standard have demonstrated ability to: - plan configuration of a distributed control system to implement a specified control scheme; - implement configuration of a distributed control system; - test and commission the configuration of a distributed control system; and - document the configuration of a distributed control system.

Standard-setting body:

Te Pūkenga - New Zealand Institute of Skills and Technology

Maintain complex control systems
This standard has expired and is no longer available.

Version 2

19237 Unit Standard 10 Credits

View Education Organisations with Consent to Assess  »

This unit standard is intended for use in the training and assessment of industrial measurement and control technicians beyond the knowledge and skills included in the National Certificate in Industrial Measurement and Control (Level 4) [Ref: 0410]. People credited with this unit standard have demonstrated ability to: - calibrate and adjust complex control systems; - perform routine maintenance on complex control systems; - diagnose and correct faults in complex control systems; and - prepare maintenance procedures for complex control systems.

Standard-setting body:

Te Pūkenga - New Zealand Institute of Skills and Technology

Data as at 2024-04-25 23:01:13.2